Single Pipeline SP116 Main technical data: 1. Dimension: 380×220×140mm, 2. Input voltage: 200V~240V AC or 100V~120V AC, Power: ≤3W, 3. Range of temperature measuring: PT1000 : 0~199℃ NTC10K: 0~99℃ 4. Input signals: 1 x PT1000 sensor temperature probe ≤500℃, silicon cable ≤280℃; 2 x NTC10K sensor temperature probe≤135℃, PVC cable ≤105℃ 5. Output signals: 1 x Auxiliary heating output (Max. load current: 12A) 2 x Relay output (Max. load current: 3A) 6. System design pressure: 1 Mpa, Safety valve respond pressure: 0.6 Mpa 7. WILO pump model: RS15/6, Screw coupling: 1/2〞 Main functions: 1. Time display, Temperature difference circulation 2. Storage tank overheating protection, Emergent stop of system overheating 3, Frost protection of pipeline and collector 4, Holiday function, Anti-bacteria function 5, Three speed levels on circulation pump, Display flow rate, Display system pressure Double Pipeline SP226 Main technical data: 1. Dimension: 450×310×150mm 2. Input voltage: 200V~240V AC or 100V~120V AC, Power: ≤3W 3. Accuracy of temperature measuring: ±1℃ 4. Range of temperature measuring: PT1000 : 0~199℃ NTC10K: 0~99℃ 5. Input signals: 1 x PT1000 sensor temperature probe ≤500℃, silicon cable ≤280℃; 2 x NTC10K sensor temperature probe≤135℃, PVC cable ≤105℃ 6 Output signals: 1 x Auxiliary heating output (Max. load current: 12A) 2 x Relay output (Max. load current: 3A) 7. System design pressure: 1 Mpa, Safety valve respond pressure: 0.6 Mpa 8. WILO pump model: RS15/6 , Screw coupling: 1/2〞 Main functions 1. Time display, Temperature difference circulation 2. Temperature difference circulation 3. Storage tank overheating protection